Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Biomech Model Mechanobiol ; 21(1): 363-381, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35037114

RESUMO

Isolated post-capillary pulmonary hypertension (Ipc-PH) occurs due to left heart failure, which contributes to 1 out of every 9 deaths in the United States. In some patients, through unknown mechanisms, Ipc-PH transitions to combined pre-/post-capillary PH (Cpc-PH) and is associated with a dramatic increase in mortality. Altered mechanical forces and subsequent biological signaling in the pulmonary vascular bed likely contribute to the transition from Ipc-PH to Cpc-PH. However, even in a healthy pulmonary circulation, the mechanical forces in the smallest vessels (the arterioles, capillary bed, and venules) have not been quantitatively defined. This study is the first to examine this question via a computational fluid dynamics model of the human pulmonary arteries, arterioles, venules, and veins. Using this model, we predict temporal and spatial dynamics of cyclic stretch and wall shear stress with healthy and diseased hemodynamics. In the normotensive case for large vessels, numerical simulations show that large arteries have higher pressure and flow than large veins, as well as more pronounced changes in area throughout the cardiac cycle. In the microvasculature, shear stress increases and cyclic stretch decreases as vessel radius decreases. When we impose an increase in left atrial pressure to simulate Ipc-PH, shear stress decreases and cyclic stretch increases as compared to the healthy case. Overall, this model predicts pressure, flow, shear stress, and cyclic stretch that providing a way to analyze and investigate hypotheses related to disease progression in the pulmonary circulation.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Pressão Sanguínea , Insuficiência Cardíaca/complicações , Hemodinâmica , Humanos , Artéria Pulmonar
3.
Am J Physiol Heart Circ Physiol ; 321(2): H318-H338, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34142886

RESUMO

Chronic thromboembolic pulmonary hypertension (CTEPH) is caused by recurrent or unresolved pulmonary thromboemboli, leading to perfusion defects and increased arterial wave reflections. CTEPH treatment aims to reduce pulmonary arterial pressure and reestablish adequate lung perfusion, yet patients with distal lesions are inoperable by standard surgical intervention. Instead, these patients undergo balloon pulmonary angioplasty (BPA), a multisession, minimally invasive surgery that disrupts the thromboembolic material within the vessel lumen using a catheter balloon. However, there still lacks an integrative, holistic tool for identifying optimal target lesions for treatment. To address this insufficiency, we simulate CTEPH hemodynamics and BPA therapy using a multiscale fluid dynamics model. The large pulmonary arterial geometry is derived from a computed tomography (CT) image, whereas a fractal tree represents the small vessels. We model ring- and web-like lesions, common in CTEPH, and simulate normotensive conditions and four CTEPH disease scenarios; the latter includes both large artery lesions and vascular remodeling. BPA therapy is simulated by simultaneously reducing lesion severity in three locations. Our predictions mimic severe CTEPH, manifested by an increase in mean proximal pulmonary arterial pressure above 20 mmHg and prominent wave reflections. Both flow and pressure decrease in vessels distal to the lesions and increase in unobstructed vascular regions. We use the main pulmonary artery (MPA) pressure, a wave reflection index, and a measure of flow heterogeneity to select optimal target lesions for BPA. In summary, this study provides a multiscale, image-to-hemodynamics pipeline for BPA therapy planning for patients with inoperable CTEPH. NEW & NOTEWORTHY This article presents novel computational framework for predicting pulmonary hemodynamics in chronic thromboembolic pulmonary hypertension. The mathematical model is used to identify the optimal target lesions for balloon pulmonary angioplasty, combining simulated pulmonary artery pressure, wave intensity analysis, and a new quantitative metric of flow heterogeneity.


Assuntos
Hemodinâmica , Hipertensão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia , Angioplastia com Balão , Doença Crônica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , Modelos Cardiovasculares , Modelos Teóricos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia
4.
Proc Inst Mech Eng H ; 234(11): 1312-1329, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32720558

RESUMO

Detection and monitoring of patients with pulmonary hypertension, defined as a mean blood pressure in the main pulmonary artery above 25 mmHg, requires a combination of imaging and hemodynamic measurements. This study demonstrates how to combine imaging data from microcomputed tomography images with hemodynamic pressure and flow waveforms from control and hypertensive mice. Specific attention is devoted to developing a tool that processes computed tomography images, generating subject-specific arterial networks in which one-dimensional fluid dynamics modeling is used to predict blood pressure and flow. Each arterial network is modeled as a directed graph representing vessels along the principal pathway to ensure perfusion of all lobes. The one-dimensional model couples these networks with structured tree boundary conditions representing the small arteries and arterioles. Fluid dynamics equations are solved in this network and compared to measurements of pressure in the main pulmonary artery. Analysis of microcomputed tomography images reveals that the branching ratio is the same in the control and hypertensive animals, but that the vessel length-to-radius ratio is significantly lower in the hypertensive animals. Fluid dynamics predictions show that in addition to changed network geometry, vessel stiffness is higher in the hypertensive animal models than in the control models.


Assuntos
Hipertensão Pulmonar , Artéria Pulmonar , Animais , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipóxia , Camundongos , Modelos Cardiovasculares , Artéria Pulmonar/diagnóstico por imagem , Microtomografia por Raio-X
5.
J R Soc Interface ; 16(159): 20190284, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31575347

RESUMO

Computational fluid dynamics (CFD) models are emerging tools for assisting in diagnostic assessment of cardiovascular disease. Recent advances in image segmentation have made subject-specific modelling of the cardiovascular system a feasible task, which is particularly important in the case of pulmonary hypertension, requiring a combination of invasive and non-invasive procedures for diagnosis. Uncertainty in image segmentation propagates to CFD model predictions, making the quantification of segmentation-induced uncertainty crucial for subject-specific models. This study quantifies the variability of one-dimensional CFD predictions by propagating the uncertainty of network geometry and connectivity to blood pressure and flow predictions. We analyse multiple segmentations of a single, excised mouse lung using different pre-segmentation parameters. A custom algorithm extracts vessel length, vessel radii and network connectivity for each segmented pulmonary network. Probability density functions are computed for vessel radius and length and then sampled to propagate uncertainties to haemodynamic predictions in a fixed network. In addition, we compute the uncertainty of model predictions to changes in network size and connectivity. Results show that variation in network connectivity is a larger contributor to haemodynamic uncertainty than vessel radius and length.


Assuntos
Algoritmos , Simulação por Computador , Hemodinâmica , Hipertensão Pulmonar , Modelos Cardiovasculares , Artéria Pulmonar , Microtomografia por Raio-X , Animais , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Masculino , Camundongos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia
6.
Biomech Model Mechanobiol ; 18(1): 219-243, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30284059

RESUMO

This study uses a one-dimensional fluid dynamics arterial network model to infer changes in hemodynamic quantities associated with pulmonary hypertension in mice. Data for this study include blood flow and pressure measurements from the main pulmonary artery for 7 control mice with normal pulmonary function and 5 mice with hypoxia-induced pulmonary hypertension. Arterial dimensions for a 21-vessel network are extracted from micro-CT images of lungs from a representative control and hypertensive mouse. Each vessel is represented by its length and radius. Fluid dynamic computations are done assuming that the flow is Newtonian, viscous, laminar, and has no swirl. The system of equations is closed by a constitutive equation relating pressure and area, using a linear model derived from stress-strain deformation in the circumferential direction assuming that the arterial walls are thin, and also an empirical nonlinear model. For each dataset, an inflow waveform is extracted from the data, and nominal parameters specifying the outflow boundary conditions are computed from mean values and characteristic timescales extracted from the data. The model is calibrated for each mouse by estimating parameters that minimize the least squares error between measured and computed waveforms. Optimized parameters are compared across the control and the hypertensive groups to characterize vascular remodeling with disease. Results show that pulmonary hypertension is associated with stiffer and less compliant proximal and distal vasculature with augmented wave reflections, and that elastic nonlinearities are insignificant in the hypertensive animal.


Assuntos
Hemodinâmica , Hipertensão Pulmonar/fisiopatologia , Modelos Biológicos , Animais , Impedância Elétrica , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Camundongos Endogâmicos C57BL , Dinâmica não Linear , Pressão , Microtomografia por Raio-X
7.
Physiol Meas ; 39(1): 014004, 2018 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-29176040

RESUMO

OBJECTIVE: Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using methods based on frequency or time domain analysis. Applications of these methods under different physiological and pathological conditions in species with different body sizes and heart rates show that the two approaches do not always agree. In this study, we have investigated the discrepancies between frequency and time domain estimates accounting for uncertainties associated with experimental processes and physiological conditions. APPROACH: We have used published data measured in different species including humans, dogs, and mice to investigate: (a) the effects of time delay and signal noise in the pressure-flow data, (b) uncertainties about the blood flow conditions, (c) periodicity of the cardiac cycle versus the breathing cycle, on the frequency and time domain estimates of Zc, and (d) if discrepancies observed under different hemodynamic conditions can be eliminated. Main results and Significance: We have shown that the frequency and time domain estimates are not equally sensitive to certain characteristics of hemodynamic signals including phase lag between pressure and flow, signal to noise ratio and the end of systole retrograde flow. The discrepancies between two types of estimates are inherent due to their intrinsically different mathematical expressions and therefore it is impossible to define a criterion to resolve such discrepancies. Considering the interpretation and role of Zc as an important hemodynamic parameter, we suggest that the frequency and time domain estimates should be further assessed as two different hemodynamic parameters in a future study.


Assuntos
Impedância Elétrica , Hemodinâmica , Animais , Pressão Sanguínea , Cães , Coração/fisiologia , Humanos , Camundongos , Análise de Onda de Pulso , Razão Sinal-Ruído , Fatores de Tempo
8.
Biomech Model Mechanobiol ; 15(5): 1245-61, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26792789

RESUMO

Individualized modeling and simulation of blood flow mechanics find applications in both animal research and patient care. Individual animal or patient models for blood vessel mechanics are based on combining measured vascular geometry with a fluid structure model coupling formulations describing dynamics of the fluid and mechanics of the wall. For example, one-dimensional fluid flow modeling requires a constitutive law relating vessel cross-sectional deformation to pressure in the lumen. To investigate means of identifying appropriate constitutive relationships, an automated segmentation algorithm was applied to micro-computerized tomography images from a mouse lung obtained at four different static pressures to identify the static pressure-radius relationship for four generations of vessels in the pulmonary arterial network. A shape-fitting function was parameterized for each vessel in the network to characterize the nonlinear and heterogeneous nature of vessel distensibility in the pulmonary arteries. These data on morphometric and mechanical properties were used to simulate pressure and flow velocity propagation in the network using one-dimensional representations of fluid and vessel wall mechanics. Moreover, wave intensity analysis was used to study effects of wall mechanics on generation and propagation of pressure wave reflections. Simulations were conducted to investigate the role of linear versus nonlinear formulations of wall elasticity and homogeneous versus heterogeneous treatments of vessel wall properties. Accounting for heterogeneity, by parameterizing the pressure/distention equation of state individually for each vessel segment, was found to have little effect on the predicted pressure profiles and wave propagation compared to a homogeneous parameterization based on average behavior. However, substantially different results were obtained using a linear elastic thin-shell model than were obtained using a nonlinear model that has a more physiologically realistic pressure versus radius relationship.


Assuntos
Artéria Pulmonar/fisiologia , Animais , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo/fisiologia , Camundongos , Dinâmica não Linear , Análise Numérica Assistida por Computador , Pressão , Reprodutibilidade dos Testes , Estresse Mecânico
9.
J Math Biol ; 71(6-7): 1525-49, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25754476

RESUMO

Experiments using wave intensity analysis suggest that the pulmonary circulation in sheep and dogs is characterized by negative or open-end type wave reflections, that reduce the systolic pressure. Since the pulmonary physiology is similar in most mammals, including humans, we test and verify this hypothesis by using a subject specific one-dimensional model of the human pulmonary circulation and a conventional wave intensity analysis. Using the simulated pressure and velocity, we also analyse the performance of the P-U loop and sum of squares techniques for estimating the local pulse wave velocity in the pulmonary arteries, and then analyse the effects of these methods on linear wave separation in the main pulmonary artery. P-U loops are found to provide much better estimates than the sum of squares technique at proximal locations, but both techniques accumulate progressive error at distal locations away from heart, particularly near junctions. The pulse wave velocity estimated using the sum of squares method also gives rise to an artificial early systolic backward compression wave. Finally, we study the influence of three types of pulmonary hypertension viz. pulmonary arterial hypertension, chronic thromboembolic pulmonary hypertension and pulmonary hypertension associated with hypoxic lung disease. Simulating these conditions by changing the relevant parameters in the model and then applying the wave intensity analysis, we observe that for each group the early systolic backward decompression wave reflected from proximal junctions is maintained, whilst the initial forward compression and the late systolic backward compression waves amplify with increasing pathology and contribute significantly to increases in systolic pressure.


Assuntos
Modelos Cardiovasculares , Artéria Pulmonar/fisiologia , Algoritmos , Animais , Pressão Sanguínea/fisiologia , Simulação por Computador , Cães , Humanos , Hipertensão Pulmonar/fisiopatologia , Conceitos Matemáticos , Circulação Pulmonar/fisiologia , Análise de Onda de Pulso , Carneiro Doméstico
10.
Biomech Model Mechanobiol ; 13(5): 1137-54, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24610385

RESUMO

A novel multiscale mathematical and computational model of the pulmonary circulation is presented and used to analyse both arterial and venous pressure and flow. This work is a major advance over previous studies by Olufsen et al. (Ann Biomed Eng 28:1281-1299, 2012) which only considered the arterial circulation. For the first three generations of vessels within the pulmonary circulation, geometry is specified from patient-specific measurements obtained using magnetic resonance imaging (MRI). Blood flow and pressure in the larger arteries and veins are predicted using a nonlinear, cross-sectional-area-averaged system of equations for a Newtonian fluid in an elastic tube. Inflow into the main pulmonary artery is obtained from MRI measurements, while pressure entering the left atrium from the main pulmonary vein is kept constant at the normal mean value of 2 mmHg. Each terminal vessel in the network of 'large' arteries is connected to its corresponding terminal vein via a network of vessels representing the vascular bed of smaller arteries and veins. We develop and implement an algorithm to calculate the admittance of each vascular bed, using bifurcating structured trees and recursion. The structured-tree models take into account the geometry and material properties of the 'smaller' arteries and veins of radii ≥ 50 µm. We study the effects on flow and pressure associated with three classes of pulmonary hypertension expressed via stiffening of larger and smaller vessels, and vascular rarefaction. The results of simulating these pathological conditions are in agreement with clinical observations, showing that the model has potential for assisting with diagnosis and treatment for circulatory diseases within the lung.


Assuntos
Pressão Sanguínea/fisiologia , Análise Numérica Assistida por Computador , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Veias Pulmonares/fisiopatologia , Humanos , Hipertensão Pulmonar/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...